Architectural

SHEERFILL® V

SHEERFILL® is the trademark for a family of membranes used in permanent structures. 

Specialty: University of Laverne • LaVerne, CA

The composite is made of fiberglass and polytetrafluoroethylene (PTFE).  SHEERFILL products are available in a range of strengths and light transmission levels, providing the user with a choice of membranes to cover virtually any size structure from a full-sized stadium to a relatively small skylight.  All SHEERFILL membranes conform to rigid fire and building codes for permanent buildings.

 

 

Typical Properties*

 

Property

Value

Method

Coated Fabric Weight (oz./yd.2) 29 nominal ASTM D4851-88
Thickness (mils) 22 nominal ASTM D4851-88
Breaking Strength (lb./in.)
(Strain Rate: 2 in./min.)
  ASTM D4851-88
Dry, Warp
520 min. avg.  
Dry, Fill
590 min. avg.  
Breaking Strength After Crease Fold (lb./in.)   ASTM D4851-88
Dry, Warp
355 min. avg.  
Dry, Fill
380 min. avg.  
Trapezoidal Tear (lb.)   ASTM D4851-88
Warp
35 min. avg.  
Fill
380 min. avg.  
Solar Transmission (%) 17.5 nominal ASTM E424
Solar Reflectance (%) 72.5  nominal ASTM E424
Burning Characteristics    
Flame Spread
0 max. ASTM E84
Smoke Generation
0 max. Tunnel Test
Incombustibility of Substrates Pass ASTM E136
Fire Resistance of Roof Coverings Burning Brand Class A ASTM E108
Flame Resistance Pass NFPA 701, Small Scale
Color White (after exposure to sunlight)  
Reinforcement Construction Warp β150 2/2, Fill β150 2/3-Count W32 x F23  

* Values listed are for virgin roll goods only.  Appropriate industry safety factors need to be used to account for the in-service effects of handling, weathering, etc.

 

 